Industrial Pharmacy Laboratory
A specialized scientific and practical laboratory that simulates pharmaceutical production lines and Quality Control (QC) laboratories in pharmaceutical plants. It aims to train pharmacy students in formulating and preparing solid and liquid dosage forms, and conducting precise physical and chemical tests to ensure the quality, efficacy, and compliance of pharmaceutical preparations with global pharmacopoeias.
Powder & emulsion homogeneity
Moisture control & ash determination
Tablet strength & durability testing
Simulating in-vivo drug release
Precise concentration & purity measurement
Laboratory Environment:
- Simulating physiological conditions of the human body (37°C) to test drug disintegration and release rates from tablets and capsules.
- Applying Quality Control (QC) standards according to approved pharmacopoeias (USP, IP) and comparing generic products with original brands.
- Using homogeneous industrial mixing techniques for powders, emulsions, and pharmaceutical suspensions.
- Strict compliance with thermal and mechanical safety procedures during the operation of furnaces and rotary mixers.
Instruments Used (14 Devices):
An essential laboratory tool used in pharmaceutical manufacturing and quality control. Its primary function is to measure the time required for tablets or capsules to disintegrate into smaller particles when placed in a liquid environment simulating human body conditions.
- Quality Control & Compliance: Ensuring that tablets and capsules break down within the specified time according to pharmacopoeial standards (e.g., USP, IP).
- Disintegration Rate Determination: Measuring the time needed for solid dosage forms to turn into small particles, increasing available surface area for dissolution and absorption.
- Testing various types of solid pharmaceutical dosage forms.
The drug is placed in glass baskets moving vertically (up and down) within an aqueous medium heated to 37°C (body temperature) to simulate the stomach environment.
Used to determine the rate and extent of drug release from a pharmaceutical dosage form (such as tablets or capsules) in a specific medium simulating gastrointestinal fluids, under controlled conditions of temperature (37°C) and agitation speed.
- Evaluating drug release from tablets and capsules.
- Ensuring the quality of pharmaceutical products and compliance with standard specifications.
- Comparing generic products with original products (in vitro bioequivalence).
- Studying the effect of various factors such as pH or medium type on drug dissolution.
- Prepare the medium and place it into the vessels.
- Set the temperature to 37°C and let the device reach the required temperature.
- Set the appropriate agitation speed (RPM) according to the test type.
- Place the tablet/capsule inside the vessel, start the device, and begin timing.
- Withdraw samples at specified time intervals and analyze them (usually using UV) to find the percentage of released drug.
Used to measure a tablet's resistance to breaking or crushing—specifically, the force required to break a tablet—to evaluate its hardness and durability during manufacturing and transportation.
- Measuring tablet hardness and ensuring tablets withstand packaging, transport, and storage.
- Ensuring balance between hardness and disintegration (Hardness vs Disintegration).
- Assisting in manufacturing quality control.
- Turn on the device and ensure calibration.
- Place the tablet correctly between the device jaws and apply force gradually until the tablet breaks.
- Record the force value (usually in Newtons or kg), and repeat the process for multiple tablets to take the average.
Used to measure the tendency of tablets to crumble or erode when subjected to vibration or friction, simulating conditions they may encounter during transport and storage.
- Evaluating tablet resistance to chipping and breaking during handling and transport.
- Testing manufacturing quality especially for uncoated tablets, and detecting weak or poorly cohesive tablets.
- Weigh a specific number of tablets (usually 10–20 tablets) and record the initial weight.
- Place the tablets inside the friabilator drum.
- Set the device (usually 100 revolutions in 4 minutes) and run it.
- Remove the tablets, clean them from dust, reweigh them, and calculate the weight loss percentage (% Friability).
A device used to measure the absorption of ultraviolet (UV) or visible (Vis) light by a drug solution or compound to determine its concentration accurately.
- Measuring chemical or drug concentrations in solutions and studying drug release in dissolution tests.
- Checking pharmaceutical purity, determining maximum wavelength ($\lambda_{max}$), and assaying/comparing original vs generic samples.
- Turn on the device, let it warm up per manufacturer instructions, and select the appropriate wavelength ($\lambda_{max}$).
- Prepare the sample, place it in a clean cuvette, insert it into the holder, and close the lid.
- Read the absorbance or percentage transmittance (% Transmittance).
A device used to measure material weight with high precision in laboratories. It relies on electronic technology to display weight digitally and features high accuracy compared to traditional balances.
- Weighing solids and liquids accurately, preparing solutions with specific concentrations, and measuring chemical samples before experiments.
- Place the balance on a flat, stable surface, turn it on, and wait until zero is displayed.
- Place the sample in the container or on the balance surface, read the digital weight, and turn off/store away from dust and moisture after use.
A high-temperature electric furnace used to heat samples to very high temperatures (typically up to 1200°C or more) in a closed, enclosed environment without direct flame contact, for chemical and thermal analyses like combustion or thermal testing.
- Determining ash content in materials, analyzing metallic elements after burning organics, and high-temperature tool sterilization.
- Set the required temperature on the control panel and let the device heat up to the target.
- Place samples in heat-resistant containers (e.g., porcelain) and load/unload using heat-resistant tongs.
An electric oven used to heat and dry samples at constant, controlled temperatures (lower than Muffle furnaces), removing moisture without direct flame contact.
- Drying glassware or chemicals before weighing, determining moisture content, and low-temperature lab tool sterilization.
- Turn on the device, set the target temperature, and place samples in heat-resistant containers on designated shelves.
- Remove samples carefully using heat-resistant tongs and let them cool before weighing/handling.
A rotary mixing motor used to mix emulsions and suspensions with high efficiency. It features dual rotational movement (Planetary + Rotation) allowing homogeneous mixing without large bubbles, accurately simulating industrial mixing processes.
- Preparing pharmaceutical emulsions (O/W, W/O) and suspensions, mixing viscous materials, and studying the effect of mixing speed/duration on formula stability.
- Select appropriate blades based on mixture viscosity, place ingredients in the container, and set speed and running time.
- Run the device until a homogeneous mixture is obtained, then stop it completely before removing the mixture.
A basin containing water heated precisely to control sample temperatures, used for experiments requiring stable and homogeneous heat without direct fire or electricity contact.
- Heating chemical/biological samples, dissolving solids, and maintaining stable temperatures for precise reactions.
- Fill the basin with water to the required level, turn it on, set the temperature, and let it heat up.
- Place samples in proper holders inside the bath, monitor time/temperature, and remove carefully after completion.
An intelligent mixing motor used to agitate liquids and solutions efficiently and precisely, with digital control over speed, time, and sometimes temperature, ensuring homogeneous mixing with minimal bubbles and splashing.
- Homogeneous mixing of pharmaceutical solutions, preparing emulsions and suspensions, and minimizing variance between samples.
- Select appropriate blades and vessel, and set mixing speed and time on the digital display.
- Run the device and monitor homogenization, then stop it completely before removing the sample.
A drum mixer used to blend powders or large granules in batches inside a drum, where materials move in a circular rotating motion for homogeneous mixing without crushing granules.
- Homogeneously mixing pharmaceutical powders and preparing dry ingredients prior to compression or granulation.
- Place materials inside the drum without exceeding maximum capacity, and close securely onto the device.
- Set mixing speed and time, run the device, and stop it before opening the drum to extract materials.
A cube-shaped mixer used to blend powders and large granules safely and efficiently inside a cube to ensure uniform material distribution without fracturing them.
- Blending sensitive pharmaceutical powders and preparing dry materials before compression or industrial production without breaking them.
- Place materials inside the cube within allowable limits and close the lid tightly.
- Set speed and time, run the device until homogeneity is reached, and stop completely before opening and unloading.
Used to measure the tendency of tablets to crumble or erode when subjected to vibration or friction, simulating storage and transport conditions to ensure tablet quality before marketing.
- Evaluating tablet resistance to friability, ensuring transport durability, and detecting weak tablets before packaging.
- Weigh a specific number of tablets and record initial weight, then place them inside the rotating drum.
- Set the number of revolutions (usually 100 revolutions in 4 minutes) and run the device until completion.
- Remove tablets, clean them, reweigh, and calculate weight loss percentage.